Fiber indoor/outdoor drop cable, FTTH, 2 Fiber, Singlemode G.657.A1, Gel-free, meters jacket marking, White jacket color, Dca flame rating
                                    Specifications
                                    
                                
                                Product classification
| Regional Availability | Asia | Australia/New Zealand | EMEA | 
| Portfolio | CommScope® | 
| Product Type | Fiber drop cable | 
| Product Series | L-DN | 
General Specifications
| Cable Type | Drop | Semi-tight buffer | 
| Construction Type | Non-armored | 
| Subunit Type | Gel-free | 
| Jacket Color | White | 
| Jacket Marking | Meters | 
| Jacket Marking Method | Inkjet | 
| Jacket Marking Text | COMMSCOPE GB SMF G657A MACL9/125 S LSZH EN50575 CLASS Dca [Serial NUMBER] [METRE MARK] | 
| Subunit, quantity | 1 | 
| Fibers per Subunit, quantity | 1 | 
| Total Fiber Count | 2 | 
Dimensions
| Cable Length | 2000 m | 6561.68 ft | 
| Buffer Tube/Subunit Diameter | 0.9 mm | 0.035 in | 
| Diameter Over Jacket | 4 mm | 0.157 in | 
Representative Image
| Click on image to enlarge. | 
Material Specifications
| Jacket Material | Low Smoke Zero Halogen (LSZH) | 
Mechanical Specifications
| Minimum Bend Radius, unloaded | 60 mm | 2.362 in | 
| Tensile Load, long term, maximum | 600 N | 134.885 lbf | 
| Tensile Load, short term, maximum | 1200 N | 269.771 lbf | 
| Compression | 20 N/mm | 114.203 lbf/in | 
| Compression Test Method | IEC 60794-1 E3 | 
| Impact | 5 N-m | 44.254 in lb | 
| Impact Test Method | IEC 60794-1 E4 | 
| Strain Test Method | IEC 60794-1 E1 | 
| Twist | 5 cycles | 
| Twist Test Method | IEC 60794-1 E7 | 
Optical Specifications
| Fiber Type | G.657.A1 | 
Environmental Specifications
| Installation temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Operating Temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Storage Temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Cable Qualification Standards | IEC 60794-1-2 | 
| EN50575 CPR Cable EuroClass Fire Performance | Dca | 
| EN50575 CPR Cable EuroClass Smoke Rating | s1a | 
| EN50575 CPR Cable EuroClass Droplets Rating | d0 | 
| EN50575 CPR Cable EuroClass Acidity Rating | a1 | 
| Environmental Space | Drop | Ducted | Facade | Indoor/Outdoor | UV resistant for outdoor and Low Smoke Zero Halogen | 
| Jacket UV Resistance | UV stabilized | 
| Water Penetration | 24 h | 
| Water Penetration Test Method | IEC 60794-1 F5 | 
Environmental Test Specifications
| Temperature Cycle | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Temperature Cycle Test Method | IEC 60794-1-2 F1 | 
Packaging and Weights
| Cable weight | 20 kg/km | 13.439 lb/kft | 
Regulatory Compliance/Certifications
| Agency | Classification | 
| 
                                                                CHINA-ROHS
                                                                     | 
                                                            Below maximum concentration value | 
| REACH-SVHC | Compliant as per SVHC revision on www.commscope.com/ProductCompliance | 
| ROHS | Compliant | 
| UK-ROHS | Compliant | 
Product classification
| Regional Availability | Asia | Australia/New Zealand | EMEA | 
| Portfolio | CommScope® | 
| Product Type | Fiber drop cable | 
| Product Series | L-DN | 
General Specifications
| Cable Type | Drop | Semi-tight buffer | 
| Construction Type | Non-armored | 
| Subunit Type | Gel-free | 
| Jacket Color | White | 
| Jacket Marking | Meters | 
| Jacket Marking Method | Inkjet | 
| Jacket Marking Text | COMMSCOPE GB SMF G657A MACL9/125 S LSZH EN50575 CLASS Dca [Serial NUMBER] [METRE MARK] | 
| Subunit, quantity | 1 | 
| Fibers per Subunit, quantity | 1 | 
| Total Fiber Count | 2 | 
Dimensions
| Cable Length | 2000 m | 6561.68 ft | 
| Buffer Tube/Subunit Diameter | 0.9 mm | 0.035 in | 
| Diameter Over Jacket | 4 mm | 0.157 in | 
Representative Image
| Click on image to enlarge. | 
Material Specifications
| Jacket Material | Low Smoke Zero Halogen (LSZH) | 
Mechanical Specifications
| Minimum Bend Radius, unloaded | 60 mm | 2.362 in | 
| Tensile Load, long term, maximum | 600 N | 134.885 lbf | 
| Tensile Load, short term, maximum | 1200 N | 269.771 lbf | 
| Compression | 20 N/mm | 114.203 lbf/in | 
| Compression Test Method | IEC 60794-1 E3 | 
| Impact | 5 N-m | 44.254 in lb | 
| Impact Test Method | IEC 60794-1 E4 | 
| Strain Test Method | IEC 60794-1 E1 | 
| Twist | 5 cycles | 
| Twist Test Method | IEC 60794-1 E7 | 
Optical Specifications
| Fiber Type | G.657.A1 | 
Environmental Specifications
| Installation temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Operating Temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Storage Temperature | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Cable Qualification Standards | IEC 60794-1-2 | 
| EN50575 CPR Cable EuroClass Fire Performance | Dca | 
| EN50575 CPR Cable EuroClass Smoke Rating | s1a | 
| EN50575 CPR Cable EuroClass Droplets Rating | d0 | 
| EN50575 CPR Cable EuroClass Acidity Rating | a1 | 
| Environmental Space | Drop | Ducted | Facade | Indoor/Outdoor | UV resistant for outdoor and Low Smoke Zero Halogen | 
| Jacket UV Resistance | UV stabilized | 
| Water Penetration | 24 h | 
| Water Penetration Test Method | IEC 60794-1 F5 | 
Environmental Test Specifications
| Temperature Cycle | -30 °C to +60 °C (-22 °F to +140 °F) | 
| Temperature Cycle Test Method | IEC 60794-1-2 F1 | 
Packaging and Weights
| Cable weight | 20 kg/km | 13.439 lb/kft | 
Regulatory Compliance/Certifications
| Agency | Classification | 
| 
                                                                        CHINA-ROHS
                                                                             | 
                                                                    Below maximum concentration value | 
| REACH-SVHC | Compliant as per SVHC revision on www.commscope.com/ProductCompliance | 
| ROHS | Compliant | 
| UK-ROHS | Compliant | 
                                    Documentation & Downloads
                                    
                                
                                Declaration of Performance
Product Specification
Warranty
Declaration of Performance
Product Compliance Documentation
Product Specification
Warranty
                                    Other Ways to Browse
                                    
                                
                                
                            
                                    
                                                                                    