Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

XP4202M | 1514514

  • Available in:
  • Asia
  • Australia/New Zealand
  • EMEA
  • Latin America
  • North America

CommScope XGS-PON Remote Optical Line Terminal (R OLT) OLT with vOLT for CommScope HFC Nodes and VHubs, specifically designed for cable MSOs

Contact Us for a Quote
Specifications
Finish making your selections or clear them to view relevant specifications.
Get Connected to the Access Technologies Resource Center

Find manuals, quick guides, data sheets, videos and much more!

Explore Access Technologies Resource Center

Features and Benefits
PRELIMINARY SPECIFICATION


CommScope FLX XP4202M R-OLT Module

The XP4202 XGS-PON R-OLT (Remote Optical Line Terminal) module for CommScope HFC Nodes and VHubs is specifically designed for cable MSOs to substantially increase the ROI of their existing network infrastructure by adding high bandwidth XGS-PON based services to their legacy DOCSIS® HFC network. The R-OLT lowers the cost of deploying PON, saves space and power using existing fiber and enclosures, and drives PON based services through the last mile, enabling the migration to FTTX through seamless coexistence of RF/HFC, RFoG overlay, and digital returns all in the same node or VHub, supporting nodes with coexistent RF/PON, or VHubs with RFPON (RFoG+PON overlay) or PON-only services.

The R-OLT incorporates full traffic management and PON MAC/PHY capabilities in a compact module and utilizes standard long haul 10GE uplinks, including CWDM and DWDM options, to connect to the S-Leaf switch/router in the Converged Interconnect Network (CIN), so operators can extend the deployment of FTTX to serve customers at distances well beyond the typical 20km reach of centralized chassis-based PON, while utilizing their transport backhaul fiber resources efficiently. For subscriber access, the R-OLT includes two XGS-PON ports, each supporting coexistent symmetric 10G/10G XGS-PON, 2.4/1.2 GPON or combo mode (coexistent GPON and XGS-PON). Each XGS-PON port is fully interoperable with GPON and XGS-PON ONUs via OMCI and supports 128 ONUs for a total of 256 subscriber ONUs per R-OLT module.


CommScope FLX Virtual OLT (vOLT)

The CommScope vOLT is a virtual OLT application supporting a software-defined networking architecture (SDN) that separates theManagement plane from the control and data planes found in the physical network function (PNF) of the R-OLT. By centralizing thecontrol plane, the vOLT facilitates network management and programmability to improve scalability of operating a highly scaled, disaggregated network with PON DAA devices like the R-OLT, thus simplifying and reducing the number of interface points to operator back-office system. Key features of the vOLT include:
  • Seamless integration of the management and assurance of multiple R-OLTs resulting in a fully managed service deployment using existing operational production processes and procedures
  • Full lifecycle management of multiple R-OLTs from initial deployment through the application of services and subscriber provisioning, and integration into monitoring and network operational support systems.
  • For GPON and XGS-PON based PON services, integration into the northbound provisioning and management systems
  • Full standards-based interfaces to northbound SDN and telemetry gathering applications

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Product Type Remote OLT

General Specifications

Gen: LED Indicator, PWR Dark = Module OFF (not receiving power) | Green = Module ON (receiving power)
LED Indicator, PON Refer to TM 1512184 XE4202M Physical Installation Guide for LED indicator colors and definitions
Ports, Network Side CommScope qualified SFP+ transceivers are purchased separately | LC Duplex: Two (2) network-side optical ports (NSI Port 0 and NSI Port 1) support single-mode SFP+ (10 Gbps) cages for standard uplink applications
Ports, Subscriber Side CommScope qualified SFP+ PON transceivers are purchased separately | Each port supports up to 128 subscriber ONUs: (256 total per module, using external splitters) | Two (2) simplex bidirectional subscriber-side optical XFP plug-in ports (PON 0 and PON 1) for ITU-T G.984 GPON, ITU-T G.9807.1 XGS-PON or ITU-T G.984/G.9807.1 G/XGS-PON Combo mode optical transceiver support
Provisioning and Monitoring vOLT SDN: Cloud-based, virtualized OLT management and OMCI provisioning and monitoring control plane interface for R-OLTs and Optical Network Units (ONUs)

Dimensions

Height 38.100 mm | 1.5 in
Width 101.600 mm | 4 in
Length 165.100 mm | 6.5 in

Port Configuration

Click on image to enlarge.

Electrical Specifications

Electrical Safety Standard CAN/CSA-C22.2 No. 60950-1-07+Amd 1+Amd 2 | CAN/CSA-C22.2 No.60950-22-07+GI1 (R2012) | EN 60950-1:2006+A11+A1+A12+A2 | EN 60950-22: 2006+A11 | IEC 60950-1:2005+A1+A2 | IEC 60950-22:2005 | IEC/EN 60825-1:2014 | IEC/EN 60825-2:2004+A1+A2 | UL 60950-1-07+A1+A2 | UL 60950-22:2007 R12.11
Electrical Safety Standard Note Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Electromagnetic Compatibility (EMC) CFR 47 Part 15, Subpart B, Class A | CISPR 24 IEC/EN 55024 | CISPR 32 IEC/EN 55032 | VCCI A | VCCI B | VCCI V-32-1
Power Consumption Note 35.5 W maximum, including two (2) XFP and two (2) SFP+ transceivers operating at 10 /10 and 1/1 or Turbo Gbps
Power Requirements +24VDC and +5VDC, supplied by NH2000, NC/NH4000 VHub/UVHub platform | PS4101 or PS4102 power supplies (required), depending on the node/VHub platform used

Ordering Tree

Click on image to enlarge.

Environmental Specifications

Operating Temperature -40 °C to +60 °C (-40 °F to +140 °F)
Storage Temperature -40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity 5%–95%, non-condensing

Packaging and Weights

Weight, net 1.293 kg | 2.85 lb

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant
UK-ROHS Compliant

Product Classification

Regional Availability Asia | Australia/New Zealand | EMEA | Latin America | North America
Product Type Remote OLT

General Specifications

Gen: LED Indicator, PWR Dark = Module OFF (not receiving power) | Green = Module ON (receiving power)
LED Indicator, PON Refer to TM 1512184 XE4202M Physical Installation Guide for LED indicator colors and definitions
Ports, Network Side CommScope qualified SFP+ transceivers are purchased separately | LC Duplex: Two (2) network-side optical ports (NSI Port 0 and NSI Port 1) support single-mode SFP+ (10 Gbps) cages for standard uplink applications
Ports, Subscriber Side CommScope qualified SFP+ PON transceivers are purchased separately | Each port supports up to 128 subscriber ONUs: (256 total per module, using external splitters) | Two (2) simplex bidirectional subscriber-side optical XFP plug-in ports (PON 0 and PON 1) for ITU-T G.984 GPON, ITU-T G.9807.1 XGS-PON or ITU-T G.984/G.9807.1 G/XGS-PON Combo mode optical transceiver support
Provisioning and Monitoring vOLT SDN: Cloud-based, virtualized OLT management and OMCI provisioning and monitoring control plane interface for R-OLTs and Optical Network Units (ONUs)

Dimensions

Height 38.100 mm | 1.5 in
Width 101.600 mm | 4 in
Length 165.100 mm | 6.5 in

Electrical Specifications

Electrical Safety Standard CAN/CSA-C22.2 No. 60950-1-07+Amd 1+Amd 2 | CAN/CSA-C22.2 No.60950-22-07+GI1 (R2012) | EN 60950-1:2006+A11+A1+A12+A2 | EN 60950-22: 2006+A11 | IEC 60950-1:2005+A1+A2 | IEC 60950-22:2005 | IEC/EN 60825-1:2014 | IEC/EN 60825-2:2004+A1+A2 | UL 60950-1-07+A1+A2 | UL 60950-22:2007 R12.11
Electrical Safety Standard Note Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Electromagnetic Compatibility (EMC) CFR 47 Part 15, Subpart B, Class A | CISPR 24 IEC/EN 55024 | CISPR 32 IEC/EN 55032 | VCCI A | VCCI B | VCCI V-32-1
Power Consumption Note 35.5 W maximum, including two (2) XFP and two (2) SFP+ transceivers operating at 10 /10 and 1/1 or Turbo Gbps
Power Requirements +24VDC and +5VDC, supplied by NH2000, NC/NH4000 VHub/UVHub platform | PS4101 or PS4102 power supplies (required), depending on the node/VHub platform used

Environmental Specifications

Operating Temperature -40 °C to +60 °C (-40 °F to +140 °F)
Storage Temperature -40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity 5%–95%, non-condensing

Packaging and Weights

Weight, net 1.293 kg | 2.85 lb
Click on image to enlarge.
Click on image to enlarge.

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system
ROHS Compliant
UK-ROHS Compliant

Product Specification

Product Specification